Keyplanby CTS

Fire department portal

Where a fire prevention officer sees every registered building in the department's area, works through the review queue and approves one version at a time.

Area map and review queue

The department's area is outlined on the map. Pins show each building's plan status, and the queue lists what is waiting, oldest first.

Fire department / Map
Keyplan ZZ Demo Fire Department Fire Prevention R. Demo RD
Example Rd Sample Ave Test Line Placeholder St Station 2
All 9Awaiting review 3Returned 1
ZZ Demo Industrial, version 2
Approved 3Submitted 3Owner maintained, not reviewed 2Returned 1Dashed line: your department's area

Awaiting review

Oldest first
ZZ Demo Cold Storage
Version 1, first plan. Ammonia refrigeration room.
6 days
ZZ Demo Warehouse North
Version 3. Racking layout changed in Bay 2.
4 days
ZZ Demo Industrial
Version 2. Sodium hydroxide totes added, key box moved.
Today

Waiting on owners

2
ZZ Demo Office Tower
Returned 11 Oct with 2 comments.
2 days
ZZ Demo Arena
Yearly review date set by the owner: 2 Nov 2026.
20 days

Approving version 2

The reviewer sees what changed since the last approved version, marked on the drawing. The approval names the version and records a content check, so a later edit can never inherit it.

Fire department / Review / ZZ Demo Industrial
Keyplan ZZ Demo Fire Department Fire Prevention R. Demo RD
Review queue / ZZ Demo Industrial

ZZ Demo Industrial

100 Example Rd. Submitted today by ZZ Owner Admin. Version 1 was approved by you on 9 Oct 2026.
Return with commentsApprove version 2
Changes since version 1HazardsFeaturesGround floorMezzanineSite
Example Rd Hydrant A B C D E 1 2 3 4 Bay 1 Racking Bay 2 Racking Bay 3 Shipping and receiving Lunch room Washrooms Reception Office Riser Sprinkler Electrical Chemical storage Corrosives Flammable liquids Spill containment Propane Cylinder cage N 0 10 m Added Moved 2.1 8 3 FDC SV FACP KEY GAS ELEC EXIT EXIT EXIT

Changes since version 1

3
Chemical storage: UN1824 added

Sodium hydroxide solution, 2,000 L in 2 IBC totes. Class 8, ERG 154.

Key box moved

From the riser room door to the main entrance.

After-hours contact added

ZZ Weekend Supervisor, second in call order.

Still not matched: UN9999

Pool shock blend, 150 kg. Firefighters will see it as not found.

Department notes

Only your department sees these
East lot gate is locked after 18:00.
Use the Example Rd entrance. Captain D. Demo, 2 Oct
Add a note for crews

Approve version 2

ZZ Demo Industrial, 100 Example Rd
Version
2, published 13 Oct 2026
Content check
7c41 9e02
Approved by
R. Demo, ZZ Demo Fire Department
I reviewed version 2: drawings, stored materials, features and contacts.
1 material is not matched (UN9999). Firefighters will see it marked as not found, with no guidance.

Your approval covers version 2 only. If the owner publishes a change, the plan shows as not reviewed until you look again.

CancelApprove version 2